Origio/Planer BT37 desktop incubator is mainly applied in cell culture, especially for in vitro fertilization. The incubator provides a stable and clean environment for the embryo, ensuring that the cells are in the best conditions including temperature, humidity and air supply state.
BT37 incubator adopts premix gas - to achieve environment with the most suitable carbon dioxide and hypoxia. As a temporary home for embryos, incubators shall be able to replicate the internal conditions of the human body to reduce the adverse effects on embryos caused by changes in temperature, humidity or pH value. The accuracy and control of the incubator chamber are very important to realize the steady state in the incubator environment. BT37 desktop incubator with high accuracy can ensure that the embryos are relieved of the influence caused by temperature or pH value changes. With compact design, it can be placed anywhere in the laboratory such as the incubator in IVF workstation, etc. The culture chamber can be placed separately for the patient's embryos, increasing security. Airflow control has unique continuity, pulse and vent functions, which can optimize the culture environment and reduce gas usage.
Features
Size |
420mm (width) * 270mm (depth) * 210mm (height) |
Weight |
15.5kg |
Storage temperature |
-10°C- +50°C |
Storage humidity |
Relative humidity 5%-95%, no condensation |
Working environment |
Only used in door |
Working temperature |
Safe working temperature 15℃-40℃. Please refer to the temperature control range |
Working humidity |
Relative humidity 5%-90%, no condensation |
Altitude |
Less than 2,000m |
Pollution level |
Pollution level 2 (British Standard EN 610101-1) |
Control
Temperature control scope |
(External +5℃) Within 40℃ |
Temperature measurement accuracy |
± 0.2°C |
Temperature control accuracy |
± 0.1°C |
Flow control range |
0 ml/m -900 ml/m |
Flow accuracy |
± 10% or ± 0.3ml/m, and take the larger value |
Flow control accuracy |
± 5% or ± 0.2ml/m, and take the larger value |
Capacity
The number of Petri dishes that each culture chamber can be placed |
4 NUNC 4-hole Petri dishes |
4 NUNC 60mm Petri dishes |
|
10 NUNC 30mm Petri dishes |
|
4 MINITUB 5-hole Petri dishes |
|
4 FALCON 60mm Petri dishes |
|
4 FALCON 60mm single hole "tissue culture" Petri dishes |
Power supply
Power source |
100 -230 V~ / 50/60Hz/1.1A |
Back-up battery |
Colloid sealed lead-acid battery / 12v * 12Ah |
Gas supply
Gas supply |
Premix gas. It's usually 6% carbon dioxide, 5% oxygen, and the rest nitrogen |
Gas supply pressure |
1.5±0.15bar |
Joint |
SWAGELOK 1/4" pipe joint |
Alarm
Alarm |
Voltage-free 3-terminal output |
Remote control
LAN |
Ethernet, TCP/IP protocol. Remote PT100 sensor PT100 Class-A-EN60751. |
Remote PT100 sensor |